Skip to main content

coloX Debugger

The host-side Lua debugging + test automation channel is not a cartridge API—it is unavailable inside .clx files. It is for developers/testers and requires a build with debugging support (enabled by default in Xcode's coloXtest; usually absent from ordinary device firmware).

  • Desktop / device: Text protocol over TCP port 3563, one command per line;
  • wasm: The same commands through a page bridge.

Commands can be sent while the game runs without setting a breakpoint first; they also arrive while stopped at a breakpoint (and can refresh the display). Responses are framed with >-> / <-<:

>-> btn
btn inj=0x20 [LEFT ] left=-1
<-< btn

Contents​

  1. Connection
  2. Multiple-VM routing
  3. Lua debugging commands
  4. Test automation: button injection
  5. Test automation: gamepad injection
  6. Test automation: mouse/touch and keyboard injection
  7. Test automation: screenshots
  8. Querying input state
  9. Example session
  10. Behavior and boundaries

1. Connection​

nc 127.0.0.1 3563
help # Full command list

Any TCP-capable script/tool (python/telnet) works; one command per line, terminated by \n.

2. Multiple-VM Routing​

The BIOS menu VM and game cartridge VM share port 3563. The first VM to start claims the channel by default; to target a specific VM, list and select:

vmlist          # idx  cart            frame  target
# 0 play_menu.clx 1234
# 1 mygame.clx 567 *
vm 1 # Subsequent commands target the game VM

Destroying the target VM (switching cartridges) releases the channel automatically; the next VM to start claims it.

3. Lua Debugging Commands​

CommandAction
btCall stack
b <file:line \| func> [if cond]Breakpoint (line/function/conditional)
i b / i localBreakpoint list / locals and upvalues
n / s / fin / c / pauseStep over / step into / step out / continue / pause
l [width]List source
src [file]Source file list / contents
p <expression>Print ([var] accesses upvalues)
set <var=value>Assign a value
r <code>Execute code in the paused frame
f <level>Select a stack frame
dis / en / dDisable / enable / delete a breakpoint
uRefresh display (while stopped)

4. Test Automation: Button Injection​

btn <keys...> [duration]     Inject coloX button input
btn 0 Stop injection
btn Query current state (physical + injected)
  • Key names (case-insensitive, matching the 8 btn() positions): X Y A B CENTER LEFT RIGHT SYS; decimal/0x masks are also accepted.
  • Duration: a plain number means frames; a number with ms means milliseconds (converted to frames using cartridge target FPS, rounded up); no duration = held until btn 0.
btn LEFT A 30        # Hold Left+A for 30 frames
btn LEFT 500ms # Hold Left for 500ms
btn SYS 1 # Hold SYS for one frame (open the system menu)
btn 0 # Stop

Injection behaves exactly like physical buttons: btnp() triggers once on the first frame, holding repeats according to the cartridge's custom repeat settings; SYS triggers for only one frame. Injection overrides only the specified keys, while other keys continue passing physical input through.

5. Test Automation: Gamepad Injection​

padset <player> <keys...> [duration]    Inject input into a player's gamepad slot
padset <player> 0 Stop injection into that slot
padset Query injection state for every slot
  • Key names come from the PAD table of usemod('pad'): A B X Y L R L2 R2 L3 R3 UP DOWN LEFT RIGHT SELECT START MENU, or a numeric mask.
  • This command exists only in builds with gamepad support.
  • Injects only buttons and connection state; sticks remain centered. pad_state/pad_btn/pad_stick and the emulator's 2P path all see it—test player 2 without connecting a gamepad (NES two-player mode, gamepad input merging).
padset 1 START 1     # Press Start for one frame on player 2
padset 0 LEFT A 60 # Hold Left+A for one second on player 1 (60fps)

6. Test Automation: Mouse/Touch and Keyboard Injection​

mouse <x> <y> [buttons] [duration]    Inject mouse/touch position and button state
mouse 0 Stop injection
mouse Query
key <keyname> [duration] Inject a held key
key 0 Stop injection
key Query
  • Coordinates use the cartridge VM coordinate system (as read by cartridge mouse()), not host screen pixels;
  • buttons is a bitmask; bit 0 = left button/touch pressed, used for simulated touch clicks (middle/right bits match host mouse state);
  • Duration follows btn: frames / ms suffix / omitted = held until stopped; physical input resumes automatically on the next frame after stopping;
  • key injects a held state, with a string key name (a, up, etc.), read by the cartridge keyboard API; the cartridge's own semantics determine whether it is newly pressed.
mouse 240 120          # Move to the center and hold (not pressed)
mouse 240 120 1 30 # Hold a touch at the center for 30 frames
mouse 100 200 1 500ms # Hold for 500ms
key a 500ms # Hold a for half a second
mouse 0 # Stop (restore both position and buttons)

7. Test Automation: Screenshots​

shot              # Save coloX_shot_<frame>.bmp in the working directory
shot /tmp/a.bmp # Specify a path (spaces allowed)
  • 24bit BMP; resolution/bit depth follow the cartridge spec (1/2/4/8/16/32bpp supported).
  • Colors use the same source as the screen (including pal() changes), independent of host scaling/round cropping; comparison concerns what the cartridge actually drew.
  • Responses contain pixel data md5, usable directly in CI golden-image comparisons without reading the file:
>-> shot
shot: /tmp/a.bmp 480x480 bpp=4 md5=5f2a...c901 frame=1234
<-< shot

8. Querying Input State​

input?

All in one view: frame/FPS/cartridge name, btn() positions (merged physical and injected states), mouse (including injection state), keyboard, and each gamepad slot (connection/buttons/sticks/injection):

frame=1234 fps=target_fps cart=mygame.clx
KDown=0x20 KHeld=0x20 [LEFT ] inj=0x20 left=18
mouse=240,130 btn=0x00 hotid=0
kb=0 key='' inj(mouse)=240,130,0x01 left=15 inj(key)='' left=0
pad0: conn=1 down=0x0 lx=0 ly=0 rx=0 ry=0 inj=0x0
pad1: conn=0 down=0x0 lx=0 ly=0 rx=0 ry=0 inj=0x10

9. Example Session​

$ nc 127.0.0.1 3563
vmlist
vm 1
btn RIGHT 90
shot /tmp/menu_open.bmp
mouse 240 120 1 15 # Tap the center
btn 0
input?

10. Behavior and Boundaries​

  • Commands are processed at frame boundaries: once before each frame begins and once after drawing; injection commands (btn/padset) take effect that frame, and screenshots capture complete frames.
  • Injection is frame-exact: it occurs after physical input is committed for that frame and before cartridge code reads btn(), with no window for observing a partially updated state.
  • Injection applies only to frames with input: while paused or without button permissions, all input is empty, so injection also has no effect (consistent with that frame having no input).
  • Injection is consistent across hosts: it acts directly on the VM's button channel, with identical desktop/device/web behavior regardless of host input peripherals.
  • md5 definition: pixel data bytes (BGR, 4-byte row alignment, BMP bottom-up storage), excluding the file header; the same image has the same md5 across platforms unless palettes differ.
  • A target VM stopped at a breakpoint still processes commands.